SMOKE EXHAUST DAMPERS
SMOKE EXHAUST DAMPERS
YAWAL SMOKE EXHAUST SYSTEMS WITH ESCO ACTUATORS
o ensure protection against the harmful effects of smoke during a fire, ventilation systems are used to create smoke-free areas. This can be achieved by installing YAWAL smoke exhaust dampers.
Smoke exhaust dampers are constructed from Yawal window profiles. For operation and control within a building, specialized servomotors are utilized, tested, and certified in accordance with EN 12101-2.
Advantages of the System:
• Possibility of using servomotors with chain, rod, arm, pneumatic, or electric actuation.
• Option to use single servomotors in a synchronized tandem system.
• Improved fire safety and facilitated firefighting operations by enhancing visibility and reducing temperatures in the roof area.
• Diversity and high functionality of the employed solutions.
Compatibility with other Yawal systems.
Technical Details
Maximum dimensions of the skylight sash. | 1400 x 2300 mm |
Maximum opening angle of the smoke exhaust window. | 90˚ |
Air permeability | class 3 conf. PN-EN 12207 |
Water tightness, angles of inclination 3˚, 45˚, 75˚. | E1500 conf. PN-EN 12208 |
Wind resistance | class C3/B3 conf. PN-EN 12210 |
Weight of the sash. | up to 160 kg |
Discharge coefficients considering lateral wind effects. | which takes into account the lateral wind exit. |